OmniCure R2000Plus UV Radiometer
The OmniCure® R2000Plus UV Radiometer is the next-generation OmniCure UV measurement solution designed to deliver accurate and repeatable optical power and irradiance measurements for UV curing applications. Building on the R2000, the R2000Plus combines measurement equivalency with a modern graphical interface, USB-C connectivity, rechargeable battery operation, integrated data logging, and enhanced process control features. These capabilities help manufacturers maintain consistent curing performance, improve productivity, and simplify system calibration. The enhanced ergonomic design and large backlit LCD display provide flexibility for both handheld and tabletop use.
The OmniCure R2000Plus is compatible with additional custom sensors, including the OmniCure UV Cure Ring and OmniCure UV Cure Site Radiometer, to provide accurate process control for precision manufacturing. By enabling the output power from the Cure Ring to be measured directly at the cure site, the UV Cure Ring Radiometer helps ensure an accurate and repeatable bonding process.
The OmniCure UV Cure Site Radiometer provides precise process control by measuring the output power of a light guide or optical accessory directly at the bonding site. It measures the irradiance delivered to the substrate or joint, allowing users to more accurately monitor and control the curing process.
| Eigenschaften | Specification |
| Wellenlängenbereich | 250 nm bis 1 µm (mit geeigneter Kalibrierung) |
| Maximaler Bereich | Power: 10 mW - 12W Irradiance: 5 mW/cm² - 60 W/cm² |
| Auflösung | 0.01 mW to 0.1W depending on measurement range |
| Genauigkeit | ±5% maximum, ±0.200 W/cm² |
| Automatische Messbereichsumstellung | Automatic range selection for both Power and Irradiance measurements to maximize displayed resolutionand precision |
| Batterie | Rechargeable Li-ion Battery |
| Funktionen | Power Measurement, Irradiance Measurement, Relative Mode, Absolute Mode, One-Button S-Series Calibration, Data Logging, Supervisor Mode, Automatic Light Guide Detection, External Sensor Support, USB-C & RS-232 Communication, Firmware Upgrade Capability |
| Spektralbereich | 300 bis 600 nm |
| Kalibrierungsbereich | 320 bis 500 nm |
| Dynamik | 83 mW to 2.5W |
| Kalibrierung | Traceable to the SI units of Irradiance |
| Anschlüsse | USB-C, RS-232, Mini-DIN External Sensor Port |
| Zertifizierungen | CE marked: complies with IEC, Canadian and US Standards, RoHS compliant |
| Abmessungen (L x W x H) | 7.75 × 4.5 × 2.5 in (197 × 114 × 64 mm) |
| Gewicht | 1.32 lb (600 g) |
| Garantie | 1 Jahr |
Maintain process control and save setup time by calibrating multiple OmniCure S2000 Series systems to a preferred irradiance set point.
Achieve accurate wideband optical measurements with proprietary OmniCure detector technology.
Virtually eliminate beam profile dependence and significantly improve measurement accuracy through the proprietary OmniCure optical interface.
Support statistical process control through access to calibration data stored on the R2000Plus unit.
Store, review, and download measurement data using the integrated data log and PC Control Software.
Access measurements, calibration functions, settings, and data logs easily through a large, backlit LCD display and intuitive user interface, helping improve usability and reduce operator errors.
Connect to a PC and charge the battery via dual USB-C ports, while the rechargeable lithium-ion battery provides added convenience for everyday operation.
Support a wide range of application requirements with optional accessories, including the OmniCure Cure Ring and Cure Site Detectors.
| Eigenschaften | Specification |
| Wellenlängenbereich | 250 nm bis 1 µm (mit geeigneter Kalibrierung) |
| Maximaler Bereich | Power: 10 mW - 12W Irradiance: 5 mW/cm² - 60 W/cm² |
| Auflösung | 0.01 mW to 0.1W depending on measurement range |
| Genauigkeit | ±5% maximum, ±0.200 W/cm² |
| Automatische Messbereichsumstellung | Automatic range selection for both Power and Irradiance measurements to maximize displayed resolutionand precision |
| Batterie | Rechargeable Li-ion Battery |
| Funktionen | Power Measurement, Irradiance Measurement, Relative Mode, Absolute Mode, One-Button S-Series Calibration, Data Logging, Supervisor Mode, Automatic Light Guide Detection, External Sensor Support, USB-C & RS-232 Communication, Firmware Upgrade Capability |
| Spektralbereich | 300 bis 600 nm |
| Kalibrierungsbereich | 320 bis 500 nm |
| Dynamik | 83 mW to 2.5W |
| Kalibrierung | Traceable to the SI units of Irradiance |
| Anschlüsse | USB-C, RS-232, Mini-DIN External Sensor Port |
| Zertifizierungen | CE marked: complies with IEC, Canadian and US Standards, RoHS compliant |
| Abmessungen (L x W x H) | 7.75 × 4.5 × 2.5 in (197 × 114 × 64 mm) |
| Gewicht | 1.32 lb (600 g) |
| Garantie | 1 Jahr |
Maintain process control and save setup time by calibrating multiple OmniCure S2000 Series systems to a preferred irradiance set point.
Achieve accurate wideband optical measurements with proprietary OmniCure detector technology.
Virtually eliminate beam profile dependence and significantly improve measurement accuracy through the proprietary OmniCure optical interface.
Support statistical process control through access to calibration data stored on the R2000Plus unit.
Store, review, and download measurement data using the integrated data log and PC Control Software.
Access measurements, calibration functions, settings, and data logs easily through a large, backlit LCD display and intuitive user interface, helping improve usability and reduce operator errors.
Connect to a PC and charge the battery via dual USB-C ports, while the rechargeable lithium-ion battery provides added convenience for everyday operation.
Support a wide range of application requirements with optional accessories, including the OmniCure Cure Ring and Cure Site Detectors.