pco.edge 5.5 CLHS sCMOS Camera
The pco.edge 5.5 is a high resolution cooled sCMOS camera utilizing a CLHS interface and 10G FOL (Camera Link HS) to allow direct processing of large data transfers via a computer making it easy to securely bridge distances of up to 10 km. This camera is equipped with a 16-bit scientific CMOS sensor for capturing crisp images and precise measurements. The pco.edge 5.5 camera also comes with an option to upgrade with a water cooling system.
| Length | 123.0 mm |
| Width | 70.0 mm |
| Height | 76.0 mm |
| Weight (kg) | 0.8 |
| Dynamic Range (log) |
90.0 dB 90.0 dB 89.0 dB 89.0 dB 83.0 dB |
| Forced Air | true |
| Readout Noise RMS |
1.4 e- 1.4 e- 1.5 e- 1.5 e- 2.5 e- |
| Pixel Size (H x V) | 6.5 x 6.5 |
| Thermo Electric Cooling | true |
| Frame rate (Full Sensor) |
33.0 fps 33.0 fps 100.0 fps 100.0 fps 50.0 fps |
| Peak Quantum Efficiency | 60.0 % |
| Dark Current |
0.6 e-/s 0.6 e-/s 0.6 e-/s 0.6 e-/s 0.9 e-/s |
| Peak Quantum Efficiency Wavelength | 600.0 nm |
| Readout Noise Median |
1.0 e- 1.0 e- 1.1 e- 1.1 e- 2.2 e- |
| Sensor Technology | sCMOS FSI |
| Sensor Version | CIS2521 |
| Fullwell Capacity | 30000 e- |
| Sensor Temperature (Dark Current Reference) | 7.0 °C |
| Operational Modes |
Slow Scan: Rolling Shutter Slow Scan: Global Reset Fast Scan: Rolling Shutter Fast Scan: Global Reset Fast Scan: Global Shutter |
| Dynamic Range A/D Converter | 16 bit |
| Dynamic Range |
30000:1 30000:1 27000:1 27000:1 13500:1 |
| Resolution (H x V) | 2560 x 2160 |
| Sensor Diagonal | 21.8 mm |
| Liquid Cooling | false |
| Included Lens Mount |
C-Mount F-Mount |
| Data Interface | Camera Link HS FOL |
| Line Scanning | false |
| Global Reset | true |
| Trigger Input Signals |
external exposure start external exposure control sequence trigger acquire enable |
| Global Shutter | true |
| Region of Interest Vertical (ROI) | vertical: steps of 1 row (min. 16) |
| Non Linearity | 0.6 % |
| MTF (Theoretical) | 76.9 lp/mm |
| Optional Lens Mount |
TFL-Mount EF-Mount |
| Spectral Range Minimum | 300 nm |
| Dark Signal Non-Uniformity DSNU |
0.3 e- (rms) 0.3 e- (rms) 0.3 e- (rms) 0.3 e- (rms) 3.9 e- (rms) |
| Binning Vertical |
x2 x4 |
| Bining Method | sum |
| Binning Horizontal |
x2 x4 |
| Default Read Out Mode | Slow Scan: Rolling Shutter |
| Operating Temperature Range | +10 °C to + 40 °C |
| Photo Response Non-Uniformity PRNU | ≤ 0.34 % |
| Sensor Manufacturer | Fairchild Imaging |
| Power Supply | 24 VDC (±10 %) |
| Exposure Minimum |
500 μs 10 μs 500 μs 10 μs 10 μs |
| Sensor Dimensions (H x V) | 16.6 x 14.0 |
| Spectral Range Maximum | 1100 nm |
| A/D Conversion Factor | 0.46 e-/DN |
| Direct Mounting Distance (No Camera Flange) | 11.1 mm (±10 %) |
| Chroma | mono or color |
| Rolling Shutter | true |
| Humidity Range (Non-Condensing) | 10 % to 80 % (recommended < 65 %) |
| Trigger Cable Connector | SMA |
| Double Shutter | false |
| Read Out Mode: Set Parameter | Shutter Mode & Pixel Rate |
| Power Consumption | max. 32 W |
| Storage Temperature Range | -10 °C to +60 °C |
| Pixel Rate |
200 MPixel/s 200 MPixel/s 572 MPixel/s 572 MPixel/s 572 MPixel/s |
| Exposure Maximum |
2 s 2 s 2 s 2 s 0 s |
| Compliance Label |
CE FCC UKCA |
| Region of Interest Horizontal (ROI) | horizontal: steps of 16 columns (min. 64) |
| Trigger Output Signals |
exposure busy line |
| Part Number | 85108072201 |
- Bright-field microscopy
- Fluorescence microscopy
- Digital pathology
- Single molecule localization microscopy (SMLM) – PALM, STORM, dSTORM, GSDIM
- Lightsheet fluorescence microscopy (LSFM)
- Structured illumination microscopy (SIM)
- Calcium imaging
- Förster resonance energy transfer (FRET)
- Fluorescence recovery after photobleaching (FRAP)
- High-speed bright-field ratio imaging
- High throughput screening
- High content screening
- Biochip reading
- Total internal reflection microscopy (TITF)
- Spinning disk confocal microscopy
- 3D metrology
- Ophthalmology
- Photovoltaic inspection
- Industrial quality inspection
- Wafer inspection
- Image intensifier imaging
- Lucky astronomy
- Disaster recovery
- Tunnel inspection
- Particle tracking velocimetry (PTV)




| Length | 123.0 mm |
| Width | 70.0 mm |
| Height | 76.0 mm |
| Weight (kg) | 0.8 |
| Dynamic Range (log) |
90.0 dB 90.0 dB 89.0 dB 89.0 dB 83.0 dB |
| Forced Air | true |
| Readout Noise RMS |
1.4 e- 1.4 e- 1.5 e- 1.5 e- 2.5 e- |
| Pixel Size (H x V) | 6.5 x 6.5 |
| Thermo Electric Cooling | true |
| Frame rate (Full Sensor) |
33.0 fps 33.0 fps 100.0 fps 100.0 fps 50.0 fps |
| Peak Quantum Efficiency | 60.0 % |
| Dark Current |
0.6 e-/s 0.6 e-/s 0.6 e-/s 0.6 e-/s 0.9 e-/s |
| Peak Quantum Efficiency Wavelength | 600.0 nm |
| Readout Noise Median |
1.0 e- 1.0 e- 1.1 e- 1.1 e- 2.2 e- |
| Sensor Technology | sCMOS FSI |
| Sensor Version | CIS2521 |
| Fullwell Capacity | 30000 e- |
| Sensor Temperature (Dark Current Reference) | 7.0 °C |
| Operational Modes |
Slow Scan: Rolling Shutter Slow Scan: Global Reset Fast Scan: Rolling Shutter Fast Scan: Global Reset Fast Scan: Global Shutter |
| Dynamic Range A/D Converter | 16 bit |
| Dynamic Range |
30000:1 30000:1 27000:1 27000:1 13500:1 |
| Resolution (H x V) | 2560 x 2160 |
| Sensor Diagonal | 21.8 mm |
| Liquid Cooling | false |
| Included Lens Mount |
C-Mount F-Mount |
| Data Interface | Camera Link HS FOL |
| Line Scanning | false |
| Global Reset | true |
| Trigger Input Signals |
external exposure start external exposure control sequence trigger acquire enable |
| Global Shutter | true |
| Region of Interest Vertical (ROI) | vertical: steps of 1 row (min. 16) |
| Non Linearity | 0.6 % |
| MTF (Theoretical) | 76.9 lp/mm |
| Optional Lens Mount |
TFL-Mount EF-Mount |
| Spectral Range Minimum | 300 nm |
| Dark Signal Non-Uniformity DSNU |
0.3 e- (rms) 0.3 e- (rms) 0.3 e- (rms) 0.3 e- (rms) 3.9 e- (rms) |
| Binning Vertical |
x2 x4 |
| Bining Method | sum |
| Binning Horizontal |
x2 x4 |
| Default Read Out Mode | Slow Scan: Rolling Shutter |
| Operating Temperature Range | +10 °C to + 40 °C |
| Photo Response Non-Uniformity PRNU | ≤ 0.34 % |
| Sensor Manufacturer | Fairchild Imaging |
| Power Supply | 24 VDC (±10 %) |
| Exposure Minimum |
500 μs 10 μs 500 μs 10 μs 10 μs |
| Sensor Dimensions (H x V) | 16.6 x 14.0 |
| Spectral Range Maximum | 1100 nm |
| A/D Conversion Factor | 0.46 e-/DN |
| Direct Mounting Distance (No Camera Flange) | 11.1 mm (±10 %) |
| Chroma | mono or color |
| Rolling Shutter | true |
| Humidity Range (Non-Condensing) | 10 % to 80 % (recommended < 65 %) |
| Trigger Cable Connector | SMA |
| Double Shutter | false |
| Read Out Mode: Set Parameter | Shutter Mode & Pixel Rate |
| Power Consumption | max. 32 W |
| Storage Temperature Range | -10 °C to +60 °C |
| Pixel Rate |
200 MPixel/s 200 MPixel/s 572 MPixel/s 572 MPixel/s 572 MPixel/s |
| Exposure Maximum |
2 s 2 s 2 s 2 s 0 s |
| Compliance Label |
CE FCC UKCA |
| Region of Interest Horizontal (ROI) | horizontal: steps of 16 columns (min. 64) |
| Trigger Output Signals |
exposure busy line |
| Part Number | 85108072201 |
- Bright-field microscopy
- Fluorescence microscopy
- Digital pathology
- Single molecule localization microscopy (SMLM) – PALM, STORM, dSTORM, GSDIM
- Lightsheet fluorescence microscopy (LSFM)
- Structured illumination microscopy (SIM)
- Calcium imaging
- Förster resonance energy transfer (FRET)
- Fluorescence recovery after photobleaching (FRAP)
- High-speed bright-field ratio imaging
- High throughput screening
- High content screening
- Biochip reading
- Total internal reflection microscopy (TITF)
- Spinning disk confocal microscopy
- 3D metrology
- Ophthalmology
- Photovoltaic inspection
- Industrial quality inspection
- Wafer inspection
- Image intensifier imaging
- Lucky astronomy
- Disaster recovery
- Tunnel inspection
- Particle tracking velocimetry (PTV)




Subscribe Now!
Floating Web Forms block
Join the PCO Circular newsletter for early access to insights on our high‑performance imaging cameras. Receive the latest application notes, expert webinars, technical articles, educational videos, product innovations, and industry events designed for scientific, microscopy, research, and industrial imaging applications.