pco.pixelfly 10 bi CLHS Camera
The pco.pixelfly 10 bi CLHS is a high-performance camera designed for scientific and industrial applications. It captures fine detail across a 23 mm sensor diagonal at full 4416 × 2368-pixel resolution and up to 57 frames per second, enabling accurate visualization of fast processes and dynamic events. Its air-cooled design eliminates the complexity and maintenance requirements of liquid cooling while maintaining industry-leading low-noise performance for superior data reliability in demanding environments.
The pco.pixelfly 10 bi CLHS delivers top-tier performance at a more accessible price point. It delivers exceptional image quality in a compact, air-cooled housing, offering laboratories and OEM integrators a cost-effective, high-performance alternative for precision imaging in a space-saving design.
Available with either a monochrome or color sensor, the camera provides outstanding sensitivity in space-constrained environments, making it ideal for applications in research, quality inspection, and machine vision.
| Length | 100.0 mm |
| Width | 80.0 mm |
| Height | 80.0 mm |
| Weight (kg) | 0.9 |
| Dynamic Range (log) | 83.0 dB |
| Forced Air | true |
| Readout Noise RMS | 1.2 e- |
| Pixel Size (H x V) | 4.6 x 4.6 |
| Thermo Electric Cooling | false |
| Frame rate (Full Sensor) | 57.0 fps |
| Peak Quantum Efficiency | 82.0 % |
| Dark Current | 6.2 e-/s |
| Peak Quantum Efficiency Wavelength | 500.0 nm |
| Readout Noise Median | 1.2 e- |
| Sensor Technology | sCMOS BSI |
| Sensor Version | LTN4323 |
| Fullwell Capacity | 14000 e- |
| Sensor Temperature (Dark Current Reference) | 35.0 °C |
| Operational Modes | Standard |
| Dynamic Range A/D Converter | 16 bit |
| Dynamic Range | 14000:1 |
| Resolution (H x V) | 4416 x 2368 |
| Sensor Diagonal | 23.0 mm |
| Liquid Cooling | false |
| Included Lens Mount |
C-Mount F-Mount |
| Data Interface | Camera Link HS FOL |
| Line Scanning | false |
| Global Reset | false |
| Trigger Input Signals |
external exposure start external exposure control acquire enable |
| Global Shutter | false |
| Region of Interest Vertical (ROI) | vertical: steps of 4 rows |
| Non Linearity | 0.2 % |
| MTF (Theoretical) | 108.6 lp/mm |
| Optional Lens Mount | TFL-Mount |
| Spectral Range Minimum | 400 nm |
| Dark Signal Non-Uniformity DSNU | ≤ 0.23 e- (rms) |
| Binning Vertical |
x2 x4 |
| Bining Method |
average sum |
| Binning Horizontal |
x2 x4 |
| Default Read Out Mode | Standard |
| Operating Temperature Range | +10 °C to +40 °C |
| Photo Response Non-Uniformity PRNU | ≤ 0.25 % |
| Sensor Manufacturer | Fairchild Imaging |
| Power Supply | 24 VDC (±10 %) |
| Exposure Minimum | 14 μs |
| Sensor Dimensions (H x V) | 20.3 x 10.8 |
| Spectral Range Maximum | 1100 nm |
| A/D Conversion Factor | 0.214 e-/DN |
| Direct Mounting Distance (No Camera Flange) | 3.4 mm (±10 %) |
| Chroma | mono |
| Rolling Shutter | true |
| Humidity Range (Non-Condensing) | 10 % to 80 % (recommended < 65 %) |
| Trigger Cable Connector | SMA |
| Double Shutter | false |
| Power Consumption | TBD |
| Storage Temperature Range | -10 °C to +60 °C |
| Pixel Rate | 596 MPixel/s |
| Exposure Maximum | 1 s |
| Compliance Label |
CE FCC UKCA |
| Region of Interest Horizontal (ROI) | horizontal: steps of 32 columns |
| Trigger Output Signals |
exposure busy line |
| Part Number | 85108076022 |
Semiconductor inspection and metrology
High-speed industrial inspection and quality control
Life sciences imaging for microscopy, fluorescence, and live-cell imaging
Scientific research
Machine vision systems
| Length | 100.0 mm |
| Width | 80.0 mm |
| Height | 80.0 mm |
| Weight (kg) | 0.9 |
| Dynamic Range (log) | 83.0 dB |
| Forced Air | true |
| Readout Noise RMS | 1.2 e- |
| Pixel Size (H x V) | 4.6 x 4.6 |
| Thermo Electric Cooling | false |
| Frame rate (Full Sensor) | 57.0 fps |
| Peak Quantum Efficiency | 82.0 % |
| Dark Current | 6.2 e-/s |
| Peak Quantum Efficiency Wavelength | 500.0 nm |
| Readout Noise Median | 1.2 e- |
| Sensor Technology | sCMOS BSI |
| Sensor Version | LTN4323 |
| Fullwell Capacity | 14000 e- |
| Sensor Temperature (Dark Current Reference) | 35.0 °C |
| Operational Modes | Standard |
| Dynamic Range A/D Converter | 16 bit |
| Dynamic Range | 14000:1 |
| Resolution (H x V) | 4416 x 2368 |
| Sensor Diagonal | 23.0 mm |
| Liquid Cooling | false |
| Included Lens Mount |
C-Mount F-Mount |
| Data Interface | Camera Link HS FOL |
| Line Scanning | false |
| Global Reset | false |
| Trigger Input Signals |
external exposure start external exposure control acquire enable |
| Global Shutter | false |
| Region of Interest Vertical (ROI) | vertical: steps of 4 rows |
| Non Linearity | 0.2 % |
| MTF (Theoretical) | 108.6 lp/mm |
| Optional Lens Mount | TFL-Mount |
| Spectral Range Minimum | 400 nm |
| Dark Signal Non-Uniformity DSNU | ≤ 0.23 e- (rms) |
| Binning Vertical |
x2 x4 |
| Bining Method |
average sum |
| Binning Horizontal |
x2 x4 |
| Default Read Out Mode | Standard |
| Operating Temperature Range | +10 °C to +40 °C |
| Photo Response Non-Uniformity PRNU | ≤ 0.25 % |
| Sensor Manufacturer | Fairchild Imaging |
| Power Supply | 24 VDC (±10 %) |
| Exposure Minimum | 14 μs |
| Sensor Dimensions (H x V) | 20.3 x 10.8 |
| Spectral Range Maximum | 1100 nm |
| A/D Conversion Factor | 0.214 e-/DN |
| Direct Mounting Distance (No Camera Flange) | 3.4 mm (±10 %) |
| Chroma | mono |
| Rolling Shutter | true |
| Humidity Range (Non-Condensing) | 10 % to 80 % (recommended < 65 %) |
| Trigger Cable Connector | SMA |
| Double Shutter | false |
| Power Consumption | TBD |
| Storage Temperature Range | -10 °C to +60 °C |
| Pixel Rate | 596 MPixel/s |
| Exposure Maximum | 1 s |
| Compliance Label |
CE FCC UKCA |
| Region of Interest Horizontal (ROI) | horizontal: steps of 32 columns |
| Trigger Output Signals |
exposure busy line |
| Part Number | 85108076022 |
Semiconductor inspection and metrology
High-speed industrial inspection and quality control
Life sciences imaging for microscopy, fluorescence, and live-cell imaging
Scientific research
Machine vision systems
Subscribe Now!
Floating Web Forms block
Join the PCO Circular newsletter for early access to insights on our high‑performance imaging cameras. Receive the latest application notes, expert webinars, technical articles, educational videos, product innovations, and industry events designed for scientific, microscopy, research, and industrial imaging applications.